Home / Products / Clean Air Systems

Integrated Generation · Drying · Filtration

Clean Air & Purification
Systems

Every HYG and HVTG unit combines oil-free generation, desiccant drying and sub-micron filtration in a single certified package — delivering instrument-grade compressed air straight from one source.

Dew Point ≤ -40°C 0.01μm Filtration ISO 8573-1 Class 0
Request a Quote
Absolute Purity Protocol

Four-Stage Conditioning

Compressed air is only as clean as its conditioning train. Every HYG / HVTG system processes the air through four sequential stages before it reaches your instruments.

01

Bulk Water Separation

Cyclone separator removes condensed moisture and coarse particles immediately after compression — protecting every downstream stage.

02

Desiccant Drying Core

Regenerative desiccant bed drives the dew point down to ≤ -40°C — bone-dry air that never condenses inside handpieces or surgical tools.

03

Particulate HEPA

0.01μm absolute filtration strips dust, rust and desiccant fines — air purity equivalent to Class 1 particulate per ISO 8573-1.

04

Active Carbon (Optional)

Activated carbon stage removes residual odors and volatile organics for cleanrooms, labs and odor-sensitive surgical environments.

Certified Performance

Measured. Audited. Certified.

Every unit is tested on a calibrated ISO 8573-1 test bench before dispatch. Results are documented in the unit's test certificate.

ISO 8573-1 Oil Content — Class 0 100%
Water Content — Dew Point Class 2 (≤ -40°C) 91%
Particulate Content — Class 1 (0.01μm) 100%

HYG Series — Integrated Clean Air

Oil-free generation, desiccant drying and HEPA filtration in one footprint. For clinics that need instrument-grade air without a separate dryer room.

HYG-301 integrated medical clean air unit for 1-2 chairs

HYG-301

For 1–2 chairs · ≤62 dB ultra-quiet
Flow300 L/min
Dew Point≤ -40°C
Tank50 L
Power2.2 kW
Inquire
HYG-400 integrated clean air unit for 3-4 chairs

HYG-400

For 3–4 chairs · ≤62 dB ultra-quiet
Flow400 L/min
Dew Point≤ -40°C
Tank50 L
Power3.0 kW
Inquire
HYG-1000 high capacity medical clean air unit

HYG-1000

For 7–10 chairs · ≤66 dB
Flow1000 L/min
Dew Point≤ -40°C
Tank100 L
Power7.5 kW
Inquire

HVTG Series — High-Volume Twin

Twin-element high-capacity clean air systems with dual drying towers. Built for busy clinics, dental hospitals and central distribution networks.

HVTG-900 twin clean air system for 6-9 chairs

HVTG-900

For 6–9 chairs · ≤64 dB
Flow900 L/min
Dew Point≤ -40°C
Tank100 L
Power6.0 kW
Inquire
HVTG-1200 twin clean air system for 10-12 chairs

HVTG-1200

For 10–12 chairs · ≤66 dB
Flow1200 L/min
Dew Point≤ -40°C
Tank150 L
Power9.0 kW
Inquire
HVTG-1600 flagship twin clean air system for 13-16 chairs

HVTG-1600

For 13–16 chairs · ≤68 dB
Flow1600 L/min
Dew Point≤ -40°C
Tank150 L
Power12.0 kW
Inquire
Compare at a Glance

HYG / HVTG Lineup

Every model shares the same Absolute Purity Protocol — the difference is capacity. Match your chair count to the right flow rate.

Model Chairs Flow Dew Point Tank Power Noise
HYG-301 1–2 300 L/min ≤ -40°C 50 L 2.2 kW ≤62 dB
HYG-400 3–4 400 L/min ≤ -40°C 50 L 3.0 kW ≤62 dB
HYG-1000 7–10 1000 L/min ≤ -40°C 100 L 7.5 kW ≤66 dB
HVTG-900 6–9 900 L/min ≤ -40°C 100 L 6.0 kW ≤64 dB
HVTG-1200 10–12 1200 L/min ≤ -40°C 150 L 9.0 kW ≤66 dB
HVTG-1600 13–16 1600 L/min ≤ -40°C 150 L 12.0 kW ≤68 dB

Tested at 0.8 MPa discharge pressure per ISO 1217. Dew point verified on a calibrated ISO 8573-1 test bench.

Complete Your System

Specify Your Clean Air Source